Both E6013 and E7018 are classified as all-position electrodes, but that does not mean they behave identically in every position or on every power source. E6013 is generally available for AC or DC and is often selected for general-purpose work; E7018 is a low-hydrogen electrode commonly used with DCEP, while AC use depends on the electrode formulation and the welding machine. For buyers, the practical comparison is to confirm the required position—including whether vertical-down welding is needed—and then match the electrode’s stated current type, polarity, diameter, and amperage range to the job.
Please visit our website for more information on this topic.
The classification provides useful clues, but it is not a substitute for the manufacturer’s technical data sheet. Welding procedure requirements, base metal, joint design, operator technique, and equipment also affect the suitable choice. Use the guidance below to screen options, then confirm the exact product and operating limits before placing an order.
| Comparison point | E6013 | E7018 |
|---|---|---|
| Position classification | All-position classification; check product guidance for the permitted vertical progression and electrode diameter. | All-position classification; commonly applied with vertical-up progression. Confirm the manufacturer’s position guidance. |
| Common current options | Typically AC and DC; permitted polarity depends on the specific product. | Typically DCEP; AC is suitable only when the product is designed and rated for it. |
| Classification strength figure | “60” represents a minimum tensile-strength class of 60 ksi, or 60,000 psi. | “70” represents a minimum tensile-strength class of 70 ksi, or 70,000 psi. |
| Buyer’s key check | Verify position, polarity, amperage, and the intended application. | Verify polarity or AC rating, low-hydrogen handling instructions, and procedure requirements. |
The “1” in E6013 and E7018 indicates an all-position electrode classification. It signals that the electrode is classified for welding in multiple positions, rather than only flat or horizontal work. It does not mean every diameter, machine setting, or welding progression is suitable for every position. The product data sheet and the applicable welding procedure should settle those details.
Buyers should also distinguish vertical-up from vertical-down welding. These are different progressions with different operating demands, and an all-position designation alone should not be treated as confirmation that a particular electrode is approved for both. E7018 is commonly used for vertical-up work, while vertical-down use should be confirmed explicitly for the exact electrode and procedure. When vertical-down productivity is a requirement, do not assume either product is an appropriate choice without written manufacturer guidance.
For flat and horizontal welds, both classifications may be candidates, subject to the job’s mechanical and procedural requirements. For vertical and overhead welds, consider the electrode diameter, the ability to control the weld pool, and the operator’s experience alongside the position rating. A smaller diameter may be specified for some out-of-position work, but the permitted diameter and current range must come from the product instructions and qualified procedure.
Ask the supplier to identify the recommended progression for each position, not simply to repeat “all position.” This is especially useful when a purchase will support several production lines or a mix of shop and site work. Recording the position requirement in the inquiry helps prevent a technically plausible electrode from being selected for the wrong welding method.
E6013 electrodes are commonly offered for AC and DC welding. Depending on the product, DC operation may be specified with electrode positive (DCEP), electrode negative (DCEN), or a particular permitted option; buyers should not infer polarity from the classification alone. Check the current-type marking and the manufacturer’s recommended operating range for the exact diameter.
This flexibility can make E6013 a practical candidate where the available power source or work mix varies. Still, confirm that the machine can supply the required current steadily and that the specified polarity is available. If a buyer is comparing products from different suppliers, use the same machine and procedure requirements when evaluating their data sheets.
E7018 is a low-hydrogen electrode commonly specified for DCEP. Some E7018 products are also designed for AC, but AC capability can vary by formulation and may depend on the power source’s open-circuit voltage and operating characteristics. A product labeled E7018 should therefore not automatically be treated as suitable for every AC machine.
If you are looking for more details, kindly visit TAYOR.
Because E7018 is low hydrogen, storage and exposure controls are also part of the current-and-position decision. Follow the product’s packaging and handling instructions, including any requirements for storage, rebaking, or exposure time. Do not apply a generic holding temperature or rebaking schedule across products; the manufacturer’s instructions and the qualified welding procedure take priority.
The “60” and “70” in these classifications refer to minimum tensile-strength classes: 60 ksi (60,000 psi) for E6013 and 70 ksi (70,000 psi) for E7018. These figures help distinguish the classification levels, but they do not by themselves establish the suitability of a completed joint. Buyers still need to consider the base-metal specification, required weld properties, applicable code, and approved welding procedure.
For structural or otherwise safety-critical work, select the electrode through the project specification and qualified procedure rather than choosing by classification number alone. An electrode with a higher strength classification is not automatically the better option if the procedure, base metal, hydrogen control, or position requirement does not match. Ask for the current technical documentation when the purchase is tied to a controlled application.
When comparing amperage, avoid relying on a single number detached from the electrode size and welding position. A 3.2 mm electrode, for example, must be evaluated using the manufacturer’s stated range for that specific product and the intended operating conditions. Record the chosen diameter and setting range in the purchasing or production specification so that substitutions can be assessed consistently.
E6013 is worth evaluating when the job calls for a general-purpose electrode and the selected product’s position and AC/DC capabilities match the available equipment and procedure. E7018 is a candidate when the specified application calls for its classification and low-hydrogen characteristics, and the shop can meet its current, position, and handling requirements. Neither choice should be made solely on convenience or the assumption that one classification works for every application.
Before ordering, send the supplier the required classification, welding positions and progression, power-source output, electrode diameters, and any project documentation requirements. TAYOR can help buyers review these selection details and identify the product documentation needed for a more informed comparison. For a quotation or product discussion, include your intended application and operating conditions so the inquiry can be matched to the relevant electrode specifications.
E6013 and E7018 are both classified for all-position welding, but buyers should confirm the specific permitted progression for each product. E6013 is commonly available for AC and DC, while E7018 is commonly used with DCEP and requires explicit confirmation before AC use. Compare the data sheet, machine capability, strength requirement, position, and handling instructions together, then validate the final selection against the applicable welding procedure.
The most reliable next step is to prepare a short requirement sheet with the base metal, joint position, progression, current source, electrode diameter, and project standard. Share it with your supplier and request the corresponding product data sheet before confirming the order. This makes the comparison more precise and reduces the risk of selecting an electrode that does not fit the actual welding conditions.
If you want to learn more, please visit our website How should buyers compare the welding positions and current types of E6013 and E7018?.