When comparing industrial videoscope models, request matched images of the same inspection targets, captured at the same working distance and under comparable lighting. Ask for close-up detail, low-light, reflective-surface, depth-orientation, and articulation samples, plus the original image files and the settings used to capture them. This lets your team judge whether each model can reveal the details relevant to your inspection—not merely whether its sample images look attractive. I recommend providing a representative part or a clearly described test target whenever possible.
If you are looking for more details, kindly visit our website.
Videoscope images can be influenced by the target’s surface, distance, illumination, viewing angle, and camera settings. If suppliers provide images of different objects or use different conditions, it is difficult to know whether a visible difference comes from the instrument or the test setup. A controlled comparison gives your engineering, maintenance, and procurement teams a more useful basis for discussion.
Before requesting samples, write down what your inspection must detect. Specify the material, the expected feature or defect, the available access path, and whether the inspection is performed in a clean, oily, wet, or otherwise challenging environment. When sharing a part is not practical, provide a drawing, representative photographs, or a description of the critical feature and its approximate size.
Ask each supplier to photograph a small, relevant feature at a stated distance from the probe tip. Suitable targets may include a surface mark, edge, fastener feature, casting detail, or a calibrated scale, depending on your application. The purpose is to determine whether the image provides enough usable detail for your inspection task, rather than to compare a general-purpose close-up.
For a consistent demonstration, you could specify a target distance such as 10 mm and ask the supplier to state how that distance was measured. This is a buyer-defined test condition, not a claim about any model’s minimum focus distance. If your work involves larger cavities or longer stand-off distances, request an additional sample at the distance that better represents the real inspection.
Request images from a dim cavity or a location where the probe’s light may not illuminate the target evenly. Include details in both the brighter and darker parts of the image, and ask the supplier to explain whether brightness, exposure, or other settings were adjusted. A bright image alone is not enough if important areas are washed out or lost in shadow.
Where feasible, define the lighting conditions used for the comparison. For example, you might request a controlled test at 100 lux around the target, while recognizing that the actual illumination at the inspection surface may differ from ambient room lighting. The value should be treated as a comparison condition that your team selects, not a universal performance threshold.
If you inspect polished metal, coated parts, or surfaces that may carry oil or moisture, request images of a representative surface in that condition. Reflections can obscure features or create bright areas, so ask the supplier to include the unedited sample and describe the probe orientation and lighting used. If your process normally cleans the part before inspection, compare samples under that same preparation routine.
Do not assume a sample of a clean, matte surface predicts performance on a reflective component. Ask for more than one viewing angle when glare is relevant, and note whether the supplier changed the angle, light output, or image settings between captures. These details help you judge whether the improvement comes from the equipment or from a change in setup.
Request samples showing how a feature appears when the probe approaches it from the directions your access route permits. A defect may be easier to interpret from one angle than another, and the probe’s ability to reach that angle is distinct from image quality alone. Ask for a short explanation of the insertion route and probe-tip orientation for each image.
If articulation is important, request a sequence that shows the same target from several positions, rather than a single best-angle image. A useful protocol might include captures at 0°, 45°, and 90° of the articulation control, if those positions are available on the model being evaluated. These are suggested comparison points; confirm the model’s actual articulation range and operating method with the supplier.
Goto Coantec to know more.
Ask for images of features with meaningful depth, such as a recess, groove, hole edge, or surface transition. A two-dimensional image may not communicate depth reliably, so consider requesting a sequence from different viewpoints or a video clip that shows movement around the feature. This can help your inspectors decide whether the image is sufficient for the task or whether another inspection method is needed.
Request a scale or known reference feature in at least one sample if approximate size matters. Clarify whether the reference is in the same plane as the feature being judged, because perspective can affect apparent dimensions. Do not use a sample image alone to establish measurement accuracy unless the system and measurement procedure have been specifically evaluated for that purpose.
Whenever possible, submit a representative component or a target that reproduces the critical surface and access conditions. Ask suppliers to return still images and a short video showing how the probe is moved, focused, and positioned. A video can reveal motion blur, image stability, and the ease of maintaining a useful view, though it does not replace controlled still-image comparisons.
Ask for original, unedited files in a commonly usable format, together with the model name, probe configuration, working distance, lighting conditions, and any relevant capture settings. If the supplier can provide only compressed or annotated images, request that limitation be stated. Keep a record of the test setup so your team can repeat the evaluation if models or configurations change.
Send every supplier the same target description, access constraints, requested sample list, and file requirements. State whether you want the supplier to use its standard settings or to optimize the image, and ask it to identify any changes made. If you request both standard and optimized samples, label them separately so the comparison remains transparent.
Use a simple review sheet with criteria such as feature visibility, glare, shadow detail, focus, image consistency, and ease of interpreting the target. Have the people who will use the instrument review the same files independently before discussing scores. Record uncertainty as well as positive findings; a sample that does not answer a critical question is a reason to request another test, not to assume success or failure.
A clear image does not prove that a videoscope can reach the inspection point or tolerate the operating environment. Evaluate insertion tube diameter and length, probe flexibility, articulation, tip options, illumination controls, display workflow, and any required documentation alongside the images. Confirm the relevant specifications and operating limits for the exact configuration being quoted.
Also establish whether the sample was captured using the proposed model and probe configuration. A supplier may have multiple models or options, so an image without configuration details is hard to connect to a purchasing decision. Ask the supplier to identify what is included in the quotation and what would require a different configuration.
The most useful samples to request are matched images of fine details, dim or shadowed areas, reflective surfaces, different viewing angles, and depth-related features, captured on targets that resemble your inspection work. Ask for original files, the exact model and probe configuration, and the distance, lighting, orientation, and settings used for each image. Use the same test brief for every supplier, then assess access and workflow separately from image quality.
As a next step, prepare a short inspection brief with your part material, critical features, access route, and operating conditions. Share it with Coantec when requesting sample images or discussing an industrial videoscope configuration, and ask which details the supplier needs to make the comparison relevant to your application. If sample images leave a critical question unanswered, request a controlled demonstration or trial before finalizing your shortlist.
For more information, please visit What Image Samples to Request When Comparing Industrial Videoscope Models.